BioPointe Reader
Installation Guide
Keri Systems, Inc.
1
01956-001 Rev. A
www.kerisys.com
What’s in this Guide
Installation Steps 1
Key Parts of the BioPointe Reader 2
Cabling Requirements 3
Power Connection 3
PXL-500W Wiegand Controller Connection 3
Serial Connection (RS232, RS485, or RS422) 3
Setting the DIP Switches (SW1, SW2, and SW3) 4
Connecting to the ADAM RS485 Converter 5
Connecting to LAN (Ethernet – TCP/IP) 5
Enrolling a Master User 7
Enrolling Additional Users 8
Mounting the BioPointe Unit 8
Getting Help 8
Installation Steps
Complete the following steps to install a BioPointe reader:
1. Connect the proper power.
2. Select and wire per the communication type desired.
a. Serial cable from the PC to one BioPointe reader
b. LAN connection to each BioPointe reader using LAN-50
devices
c. RS485 connection to one or more BioPointe readers using an
ADAM interface device
3. Set the DIP switches for the communication type selected.
4. Enroll a master user.*
5. Enroll additional users.*
6. Connect all BioPointe readers to Keri PXL-500W (Wiegand)
controllers for door control.
7. Enroll users in the Doors program: Facility Code 0, User ID# as Card
Number, Wiegand card type.
8. Perform a Total Update in the Doors program to download all user
information to the Keri controllers.
*Note: These steps may be performed using BioPointe Central software.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - BioPointe Reader

BioPointe ReaderInstallation GuideKeri Systems, Inc.101956-001 Rev. Awww.kerisys.comWhat’s in this GuideInstallation Steps 1Key Parts of the BioPointe

Page 2 - 01956-001 Rev. A

Keri Systems, Inc.201956-001 Rev. Awww.kerisys.comKey Parts of the BioPointe ReaderThe keypad is made up of the standard numeric keys, three function

Page 3

Keri Systems, Inc.301956-001 Rev. Awww.kerisys.comCabling RequirementsBioPointe RS485: Belden 9501, 24 AWG, twisted pair, shielded.BioPointe to PXL: B

Page 4

Keri Systems, Inc.401956-001 Rev. Awww.kerisys.comSerial Connection (RS232, RS485, or RS422 – Cont.)Setting the DIP Switches (SW1, SW2, and SW3)Note:

Page 5

Keri Systems, Inc.501956-001 Rev. Awww.kerisys.comConnecting to the ADAM RS485 ConverterThe ADAM 4520 is an interface adapter, connected to the serial

Page 6

Keri Systems, Inc.601956-001 Rev. Awww.kerisys.comConnecting to LAN (Ethernet – TCP/IP – Cont.)LAN-50 Wiring ConnectionsDIP Switch SettingsSW1: Device

Page 7

Keri Systems, Inc.701956-001 Rev. Awww.kerisys.comEnrolling a Master UserWhen you first receive the device, there are no enrolled fingerprints. The fi

Page 8

Keri Systems, Inc.801956-001 Rev. Awww.kerisys.comEnrolling Additional UsersTo enroll additional users, start from Step 1, but press [Circle] [Circle]

Commentaires sur ces manuels

Pas de commentaire