Keri-systems Doors.NET Manual Manuel d'utilisateur Page 356

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 602
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 355
Doors.NET Reference Manual
- 356 -
Synchronize Clocks
The synchronization command sets the clock in all gateways and controllers to the time
set in the system PC. This command requires a System Administrator password for exe-
cution. After authentication, the following actions occur:
l Application Server will send out a synchronization command with its PC clock
(date/time) in UTC format to all connected Gateways.
l If the Gateway is not on the same PC as the Application Server, the Gateway ser-
vice will set the PC clock to the UTC reference with local time zone adjustment.
l The Gateway service will then send the new date/time to each controller.
1.
From the Setup Menu, in the Hardware icon group, click the icon. The Syn-
chronize Clocks window appears.
2. Enter your System Administrator password and click the OKButton.
3. Synchronization is automatically done, setting all Gateways and controllers to the
system PC time.
NOTE: If all of your PCs have an Internet Connection, they can be configured to auto-
matically update their clocks from time.windows.com on a weekly basis. This feature is
enabled via the Operating System's Date and Time Properties window. Set the Auto-
matically synchronize tick box and click the Apply Button.