Doors.NET Reference Manual
- 388 -
Floor Device
Wiring Loca-
tion
Terminal
Block
Default Output
Designator
Default Input
Designator
6 4x4
Bus 1 - Port
4
TB25 Output 5.4 Input 5.4
7 4x4
Bus 2 - Port
1
TB22 Output 6.1 Input 6.1
8 4x4
Bus 2 - Port
2
TB23 Output 6.2 Input 6.2
9 4x4
Bus 2 - Port
3
TB24 Output 6.3 Input 6.3
10 4x4
Bus 2 - Port
4
TB25 Output 6.4 Input 6.4
l The Output is the Door Relay for each floor.
l The Input is the Cab Request for each floor. Cab Request Inputs are only
used/wired if the cab reader is set to Elevator - With Floor Select. Use this option
when you need to know the floor that was selected; which is a different behavior
than the default option of Elevator - No Floor Select.